Power Integrations are now offering an amazing circuit implementations in power supply chips. Everything including high-voltage MOSFET, PWM controller, soft start-up circuit, oscillator, programmable current limit circuit, short-circuit and open-loop protection, gate drive for the switching MOSFET, feedback compensation circuit and thermal shutdown reducing the assembly costs. |
|
|
Power Integrations EcoSmart® IC technology enables power supply designers to meet the requirements of all existing and proposed energy efficiency standards worldwide. For the latest in energy efficiency guidelines and design solutions, visit the Power Integrations Green Room at www.powerint.com/greenroom. |
|
|
Features |
Download |
|
|
Product Selector Guide - AC-DC Products
|
|
|
|
Product Selector Guide - DC-DC Products
|
|
|
|
|
2007 Data Book and Design Guide
|
|
Design Tools
|
PI Expert™ Design Software Suite v.6.5 includes the following software tools that simplify the design of off-line power supplies and DC-DC converters based on products from Power Integrations. |
|
|
PI Expert - A powerful software program that takes a designer’s switching power supply requirements and determines the critical components needed to generate a working switch mode power supply, including the transformer design. A design can be optimized for efficiency or cost using auto design or manual control options.PI Xls Designer - provides design spreadsheet support for recently introduced Power Integrations ICs not yet included in the PI Expert Design Software tool, as well as providing a simplified spreadsheet approach for other PI products for advanced users who prefer a spreadsheet interface.PI Transformer Designer is a tool that generates detailed instructions needed by transformer vendors to construct a transformer based on designs created with PI Expert Design Software and PI XLS Designer. Intelligent shield selection is included to simplify the task of meeting EMI standards, with optimized bobbin pin assignment for ease of layout. |
PI Expert™ Design Software Suite v.6.5
To download or request a CD, go to |
|
AC/DC PRODUCTS |
|
|
|
|
|
I. VERY LOW POWER AC-DC, NON-ISOLATED LINEAR/PASSIVE SUPPLY REPLACEMENT (<360 mA) |
|
Product 1,5 |
||||||
|
LNK302 P or G |
LNK304 P, G or D |
LNK305 P or G |
LNK306 P or G |
|||
|
Output Current9 |
MDCM7 |
230 VAC ± 15% |
63 mA | 120 mA | 175 mA |
225 mA |
|
CCM8 |
80 mA | 170 mA | 280 mA | 360 mA | ||
|
Output Current9 |
MDCM7 |
85-265 VAC |
63 mA | 120 mA | 175 mA | 225 mA |
|
CCM8 |
80 mA | 170 mA | 280 mA | 360 mA | ||
|
HV-FET Rating |
700 V | 700 V | 700 V | 700 V | ||
|
Switching Frequency (kHz) |
66 | 66 | 66 | 66 | ||
|
Control Method |
ON/OFF | ON/OFF | ON/OFF | ON/OFF | ||
|
Self-Powered4 |
Y | Y | Y | Y | ||
|
Soft-Start (Y-Yes; N.R.-Not Required) |
N.R. | N.R. | N.R. | N.R. | ||
|
Adjustable Current Limit |
- | - | - | - | ||
|
Auto Restart |
- | Y | Y | Y | ||
|
Thermal Shutdown |
Hys.11 | Hys.11 | Hys.11 | Hys.11 | ||
|
Frequency Jitter |
Y | Y | Y | Y | ||
|
Power Limiting |
Y | Y | Y | Y | ||
|
Line UV Detection |
- | - | - | - | ||
|
Line OV Detection |
- | - | - | - | ||
|
Remote ON/OFF |
Y | Y | Y | Y | ||
|
EcoSmart® Low Standby/No-load Power Consumption |
Y | Y | Y | Y | ||
|
Max. Duty Cycle % (DCMAX) |
69 | 69 | 69 | 69 | ||
|
Simultaneous Line Sensing and Current Limit |
- | - | - | - | ||
|
Price |
![]() |
![]() |
![]() |
![]() |
||
Notes
|
II. VERY LOW POWER AC-DC POWER CONVERSION (UP TO 9 W) |
|
Product 1,5 |
||||||||||||||
|
P or G |
P or G |
P or G |
P or G6 |
P or G6 |
P or G6 |
LNK362 P or G |
LNK363 P or G |
LNK364 P or G |
||||||
|
Continuous Output Power9 |
Adapter2 |
230 VAC ±15% |
1.9 W |
2.5 W |
3 W |
4 W |
4 W |
4 W |
2.8 W |
5 W |
5.5 W |
|||
|
Open Frame3 |
1.9 W | 2.5 W | 3 W | - | - | - | 2.8 W | 7.5 W | 9 W | |||||
|
Continuous Output Power9 |
Adapter2 |
85-265 VAC |
1.9 W | 2.5 W | 3 W | 3 W | 3 W | 3 W | 2.6 W | 3.7 W | 4 W | |||
|
Open Frame3 |
1.9 W | 2.5 W | 3 W | - | - | - | 2.6 W | 4.7 W | 6 W | |||||
|
HV-FET Rating |
700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | |||||
|
Switching Frequency (kHz) |
66 | 83 | 100 | 42 | 42 | 42 | 132 | 132 | 132 | |||||
|
Control Method |
ON/OFF | ON/OFF | ON/OFF | PWM | PWM | PWM | ON/OFF | ON/OFF | ON/OFF | |||||
|
Self-Powered4 |
Y |
Y |
Y |
- |
- |
- |
Y |
Y |
Y |
|||||
|
Soft-Start (Y-Yes; N.R.-Not Required) |
N.R. | N.R. | N.R. | Y | Y | Y | N.R. | N.R. | N.R. | |||||
|
Adjustable Current Limit |
- | - | - | - | - | - | - | - | - | |||||
|
Auto Restart |
Y | Y | Y | Y | Y | Y | Y | Y | Y | |||||
|
Thermal Shutdown |
Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | |||||
|
Frequency Jitter |
Y | Y | Y | Y | Y | Y | ||||||||
|
Power Limiting |
Y | Y | Y | Y | Y | Y | Y | Y | Y | |||||
|
Line UV Detection |
- |
- | - | - | - | - | - | - | - | |||||
|
Line OV Detection |
- | - | - | - | - | - | - | - | - | |||||
|
Remote ON/OFF |
Y | Y | Y | Y | Y | Y | ||||||||
|
EcoSmart® Low Standby/No-load Power Consumption |
Y | Y | Y | Y | Y | Y | Y | Y | Y | |||||
|
Max. Duty Cycle % (DCMAX) |
69 | 69 | 69 | 77 | 77 | 77 | 60 | 60 | 60 | |||||
| Simultaneous Line Sensing and Current Limit | - | - | - | - | - | - | - | - | - | |||||
|
Price |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
|||||
|
III. LOW POWER AC-DC POWER CONVERSION (UP TO 36.5 W) |
|
IV. SUPER PEAK AC-DC POWER CONVERSION (UP TO 68 W CONTINUOUS, 117 W PEAK) |
|
Product 1,5 |
|||||||||
|
PKS603 P |
PKS604 P |
PKS604 Y or F |
PKS605 P |
PKS605 Y or F |
PKS606 P |
PKS606 Y or F |
|||
|
Continuous Output Power9 |
Adapter2 |
230 VAC ± 15% |
13 W | 23 W | 35 W | 31 W | 46 W | 35 W | 68 W |
|
Adapter Peak10 |
32 W | 56 W | 56 W | 60 W | 79 W | 66 W | 117 W | ||
|
Continuous Output Power9 |
Adapter2 |
85-265 VAC |
9 W | 16 W | 23 W | 21 W | 30 W | 25 W | 45 W |
|
Adapter Peak10 |
25 W | 44 W | 44 W | 44 W | 58 W | 46 W | 86 W | ||
|
HV-FET Rating |
700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | ||
|
Switching Frequency (kHz) |
277 | 277 | 277 | 277 | 277 | 277 | 277 | ||
|
Control Method |
ON/OFF | ON/OFF | ON/OFF | ON/OFF | ON/OFF | ON/OFF | ON/OFF | ||
|
Self-Powered4 |
- | - | - | - | - | - | - | ||
|
Soft-Start (Y-Yes; N.R.-Not Required) |
N.R. | N.R. | N.R. | N.R. | N.R. | N.R. | N.R. | ||
|
Adaptive Current Limit |
Y | Y | Y | Y | Y | Y | Y | ||
|
Auto Restart |
Y | Y | Y | Y | Y | Y | Y | ||
|
Thermal Shutdown |
Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | ||
|
Frequency Jitter |
Y | Y | Y | Y | Y | Y | Y | ||
|
Power Limiting |
Y | Y | Y | Y | Y | Y | Y | ||
|
Line UV Detection |
Y | Y | Y | Y | Y | Y | Y | ||
|
Adaptive On-Time Extension |
Y | Y | Y | Y | Y | Y | Y | ||
|
Peak Power Delivery |
Y | Y | Y | Y | Y | Y | Y | ||
|
EcoSmart® Low Standby/No-load Power Consumption |
Y | Y | Y | Y | Y | Y | Y | ||
|
Max. Duty Cycle % (DCMAX) |
65 | 65 | 65 | 65 | 65 | 65 | 65 | ||
|
Smart AC Sense With Latching Shutdown and Reset |
Y | Y | Y | Y | Y | Y | Y | ||
|
Price |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||
|
V. HIGH POWER AC-DC POWER CONVERSION (UP TO 290 W) |
|
Product 1,5 |
|||||||||||||
|
P or G |
TOP242 R |
Y or F |
P or G |
TOP243 R |
Y or F |
P or G |
TOP244 R |
Y or F |
TOP245 P or G |
TOP245 R |
|||
|
Continuous Output Power9 |
Adapter2 |
230 VAC ± 15% |
9 W | 21 W | 10 W | 13 W | 29 W | 20 W | 16 W | 34 W | 30 W | 19 W | 37 W |
|
Open Frame3 |
15 W | 22 W | 22 W | 25 W | 45 W | 45 W | 28 W | 50 W | 65 W | 30 W | 57 W | ||
|
Continuous Output Power9 |
Adapter2 |
85-265 VAC |
6.5 W | 11 W | 7 W | 9 W | 17 W | 15 W | 11 W | 20 W | 20 W | 13 W | 23 W |
|
Open Frame3 |
10 W | 14 W | 14 W | 15 W | 23 W | 30 W | 20 W | 28 W | 45 W | 22 W | 33 W | ||
|
HV-FET Rating |
700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | ||
|
Switching Frequency (kHz) |
132 | 132/66 | 132/66 | 132 | 132/66 | 132/66 | 132 | 132/66 | 132/66 | 132 | 132/66 | ||
|
Control Method |
PWM | PWM | PWM | PWM | PWM | PWM | PWM | PWM | PWM | PWM | PWM | ||
|
Self-Powered4 |
- | - | - | - | - | - | - | - | - | - | - | ||
|
Soft-Start (Y-Yes; N.R.-Not Required) |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Adjustable Current Limit |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Auto Restart |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Thermal Shutdown |
Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | ||
|
Frequency Jitter |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Power Limiting |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Line UV Detection |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Line OV Detection |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Remote ON/OFF |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
EcoSmart® Low Standby/No-load Power Consumption |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Max. Duty Cycle % (DCMAX) |
78 | 78 | 78 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | 65 | ||
|
Simultaneous Line Sensing and Current Limit |
- | Y | Y | - | Y | Y | - | Y | Y | - | Y | ||
|
Price |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||
|
Product 1,5 |
||||||||||||||
|
TOP245 Y or F |
TOP246 P or G |
TOP246 R |
TOP246 Y or F |
TOP247 R |
TOP247 Y or F |
TOP248 R |
TOP248 Y or F |
TOP249 R |
TOP249 Y or F |
TOP250 R |
TOP250 Y or F |
|||
|
Continuous Output Power9 |
Adapter2 |
230 VAC ± 15% |
40 W | 21 W | 40 W | 60 W | 42 W | 85 W | 43 W | 105 W | 44 W | 120 W | 45 W | 135 W |
|
Open Frame3 |
85 W | 34 W | 64 W | 125 W | 70 W | 165 W | 75 W | 205 W | 79 W | 250 W | 82 W | 290 W | ||
|
Continuous Output Power9 |
Adapter2 |
85-265 VAC |
26 W | 15 W | 26 W | 40 W | 28 W | 55 W | 30 W | 70 W | 31 W | 80 W | 32 W | 90 W |
|
Open Frame3 |
60 W | 26 W | 38 W | 90 W | 43 W | 125 W | 48 W | 155 W | 53 W | 180 W | 55 W |
210 W |
||
|
HV-FET Rating |
700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | 700 V | ||
|
Switching Frequency (kHz) |
132/66 | 132 | 132/66 | 132/66 | 132/66 | 132/66 | 132/66 | 132/66 | 132/66 | 132/66 | 132/66 | 132/66 | ||
|
Control Method |
PWM | PWM | PWM | PWM | PWM | PWM | PWM | PWM | PWM | PWM | PWM | PWM | ||
|
Self-Powered4 |
- | - | - | - | - | - | - | - | - | - | - | - | ||
|
Soft-Start (Y-Yes; N.R.-Not Required) |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Adjustable Current Limit |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Auto Restart |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Thermal Shutdown |
Hys.11 | Hys11. | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | Hys.11 | ||
|
Frequency Jitter |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Power Limiting |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Line UV Detection |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Line OV Detection |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Remote ON/OFF |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
EcoSmart® Low Standby/No-load Power Consumption |
Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
|
Max. Duty Cycle % (DCMAX) |
78 | 78 | 78 | 78 | 78 | 78 | 78 | 78 | 78 | 78 | 78 | 78 | ||
|
Simultaneous Line Sensing and Current Limit |
Y | - | Y | Y | Y | Y | Y | Y | Y | Y | Y | Y | ||
| Price |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||
|
1. Packages: P–Plastic DIP, G–Surface Mount DIP, Y–TO-220, R–TO-263, F–TO-262. Lead-free package options are available for P, G, Y, & F packages. Consult data sheet for product ordering information. 2. Minimum continuous power in a typical non-ventilated encased adapter with minimal heat sinking, measured at a device ambient of 50 ºC. 3. Minimum continuous power in an open frame with adequate heat sinking. 4. No bias winding needed for LNK500, LNK501 and LNK362-364. 5. Shipping quantities per package: Tubes: F and Y- 50 pc., P and G - 50 pc. Tape and reel: G-TL- 1000 pc., R-TL- 750 pc. R-package is available in tape and reel only. 6. Typical power ratings shown for CV/CC charger applications. LNK501 provides tighter output CC tolerances. LNK520 is optimized for EMI reduction. See data sheets for full specifications. 7. Mostly discontinuous conduction mode. 8. Continuous conduction mode. 9. Typical output current in a non-isolated buck converter. 10. Typical peak power for a period of 100 ms and a duty cycle of 10% in a non-ventilated enclosed adapter measured at +50 °C (see datasheet for details). 11. Thermal shutdown realize over hysteretic curve. |
|
DC/DC PRODUCTS |
|
|
|
Notes :1. Packages: P–Plastic DIP, G–Surface Mount DIP, R–TO-263, S–MO-169. Pb-free package options are available for P, G, & S packages. Consult data sheet for product ordering information. 2. Shipping quantities per package: Tubes: P and G - 50 pc. Tape and reel: GTL-1000 pc., R-TL- 750 pc., S-TL- 1000 pc. R-package and S-PAK are available in tape and reel only. 3. For example, in a 55 W output design, the DPA426R will dissipate a worst case total of 2.5 W. 4. See data sheet for power capability at 16 VDC and 24 VDC input. 5. Power based on diode rectification assuming worst case RDS(ON) @ TJ=100 ºC. Up to 5% higher output power possible using synchronous rectification. 6. Thermal shutdown realize over hysteretic curve. |
|
For additional information about Power Integrations products visit http://www.powerint.com. For additional technical information please write to support@comet.bg. For information about prices and delivery terms for ordering Power Integrations products, please call Comet Electronics (tel.: 00 359 2 915 58 55, fax: 00 359 2 879 32 00) or send an e-mail to office@comet.bg. |
|